Copperweld NM-B Building Wire is a welcome value to every stakeholder in the residential space.
Installed to NEC requirements, Copperweld NM-B Building Wire offers more electrical efficiency than its alternatives, pointing to lower monthly utility costs and smoother running equipment. Its light weight and flexibility create opportunities for labor savings. Disincentivizing pilferage and theft, it offers thieves only a small fraction of the scrap value of single-metal copper scrap.
Cu-Clad Aluminum (CCA) Conductor — Drawn from a copper-clad aluminum rod, with the copper metallurgically bonded to an AA 8000 series aluminum core, where oxygen-free copper forms a minimum of 10 percent of the cross-sectional area of a solid conductor or each strand of a stranded conductor.
Application Standards — UL (UL-83, UL-719, UL-1581, UL-2556); NFPA 70 (NEC®) Article 334; ASTM-B-566; NEMA RV 2-2011
Conductors — For wire sizes 12-10, solid annealed THHN Copper-Clad Aluminum with solid Copper Clad Aluminum ground. For 8 AWG sizes and larger, stranded annealed THHN Copper-Clad Aluminum with solid Copper-Clad Aluminum ground.
Conductor Insulation — Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.
Grounding Conductor — For NM-B 12-10 AWG sizes: ground will be 12-10 AWG, solid, annealed conductor. For NM-B 8 AWG sizes and larger: ground will be 8 AWG, solid, annealed.
NM-B Jacket — Made with 30-mil flame retardant and moisture resistant PVC to safety listing standards. Colors according to industry norms and specific application.
Copperweld® Copper-Clad Aluminum Type NM-B (non-metallic sheathed cable) is referenced by Article 334 of the National Electrical Code. OSHA safety listed: UL E492024. ETL listing: 5021266.
Wiring Methods: Per Article 334 of the NEC, Copperweld® Type NM-B shall not be used in wet or damp locations where an electrolyte might be present. It may only be used in dry locations for indoor wiring. Copperweld® NM-B cable should be sized per NEC ampacity table 310.16 using the 60°C column. It may be used as the primary electrical conductor for the residential branch circuit system, providing service for outlets, switches and 240 Volt appliance loads. It cannot be used as a service entry cable, nor can it be buried. Copperweld NM-B must be protected from physical damage per Article 300.4 of the NEC. It must not be installed in locations exposed to corrosive fumes or vapors. Per Article 590, Copperweld® NM-B can be used in temporary installations as feeders and branch circuits for power and lighting. Type NM-B is rated 600-volt for both exposed and concealed work in dry locations, as defined by the National Electrical Code.
Identified for use with wiring devices, splice connectors and equipment terminals rated for CC, Cu, Cu/Al and CO/ALR. When terminating with twist-on splice connectors, pre-twisting is not recommended. Torque until the wires are tight under the cap and visibly twisted together two times outside of the cap to ensure electrical contact. Do not over-torque or under-torque. Ensure secure connection limiting wire deformation. Copperweld® NM-B is made with ASTM B-566 Copper-Clad Aluminum bare wire, which carries its own component listing, RU DVVU2 and DVVV2. Copperweld NM-B conductors are suitable to terminate on 15 and 20 ampere rated wiring devices (receptacles and snap switches) marked "copper only" or "CO/ALR." For termination on devices rated 30 amperes or greater, the termination must be marked "CU/AL" or equivalent. Please consult UL Product IQ guide information RTRT and WJQR if further confirmation is required. Copperweld® NM-B may be pigtailed to single-metal copper wire in dry locations. Copperweld® NM-B cable should not be terminated with single-metal aluminum wire without the application of an oxide inhibitor or a terminal or connector specifically listed for the intermixing of dissimilar conductor metals. Copperweld® ASTM B-566 Copper-Clad Aluminum wire is not dissimilar to copper, brass or zinc-plated steel.
1
1
White
White
12 AWG
12 AWG
0.015
0.015
0.004
0.004
Allowable Ampacity @ 60° C*
15
15
Outside Diameter (in)
0.191 x 0.403
0.191 x 0.522
Approx. Weight (lb/1000 ft)
45.51
61.25
Standard Packaging
250' Coil, 1000' Wood Reel
250' Coil, 1000' Wood Reel
Standard 48x48 Pallet Qty.
108/12
81/12
1
1
Yellow
Yellow
10 AWG
10 AWG
0.020
0.020
0.004
0.004
Allowable Ampacity @ 60° C*
25
25
Outside Diameter (in)
0.222 x 0.487
0.222 x 0.637
Approx. Weight (lb/1000 ft)
67.21
89.84
Standard Packaging
250' Coil, 1000' Wood Reel
250' Coil, 1000' Wood Reel
Standard 48x48 Pallet Qty.
81/12
54/12
7
7
Orange
Orange
8 AWG
8 AWG
0.030
0.030
0.005
0.005
Allowable Ampacity @ 60° C*
35
35
Outside Diameter (in)
0.277 x 0.693
0.582
Approx. Weight (lb/1000 ft)
123.64
155.65
Standard Packaging
1000' Wood Reel
1000' Wood Reel
Standard 48x48 Pallet Qty.
10
10
7
7
Black
Black
8 AWG
8 AWG
0.030
0.030
0.005
0.005
Allowable Ampacity @ 60° C*
40
40
Outside Diameter (in)
0.314 x 0.769
0.674
Approx. Weight (lb/1000 ft)
155.65
213.06
Standard Packaging
1000' Wood Reel
1000' Wood Reel
Standard 48x48 Pallet Qty.
10
10
7
7
Black
Black
8 AWG
8 AWG
0.040
0.040
0.006
0.006
Allowable Ampacity @ 60° C*
55
55
Outside Diameter (in)
0.385 x 0.909
0.843
Approx. Weight (lb/1000 ft)
225.49
315.91
Standard Packaging
1000' Wood Reel
1000' Wood Reel
Standard 48x48 Pallet Qty.
8
4
60°C
(140°F)
75°C
(167°F)
90°C
(194°F)
White
12**
Replaces
15
20
25
14**
15
20
25
Yellow
10**
Exceeds by 5 Amps
25
30
35
12**
20
25
30
Orange
8*
Exceeds by 5 Amps
35
40
45
10**
30
35
40
Black/
Other
6
Replaces
40
50
55
8
40
50
55
Black/
Other
4
Replaces
55
65
75
6
55
65
75
CCA offers a fraction of the scrap value of copper building wire.
When sized per Code, CCA delivers improved energy efficiency over alternatives.
CCA is lightweight, flexible, and terminates to standard torquing values.
NEC compliant for 600 Volt residential branch circuit conductors since 1971.
Listed for safety for use in general electrical wiring and branch circuits.
CCA has 50 years of safe performance history in standard circuits.